< Back
  

Sheet Requirements

 
Roof area less than 25m²
Roof area 25 - 100m²  

Rafter Pitch
(degrees)

Valley Type Max. Vally
Lenght
Valley Type Valley Type
Lenght
Minimum Lap
Lenght
17.5 to 22 B/D 7.0m - - 350mm
22.5 to 29 A/B/D 7.0m B/D 14.5m 300m
30 to 34 A/B/D 7.5m B/D 15.0m 200m
35 to 39 A/B/D 7.5m B/D 15.5m 200m
40 to 44 A/B/D 8.0m B/D 16.5m 150m
45 to 49 A/B/D 8.5m B/D 17.0m 150m
50 to 55 B/D 9.0m B/D 18.5m 150m
   
Valley Weights Valley Thickness
Standard valley troughs (HD, HA, HB) 1.64kg/m² Standard valley throughs (HD,HA,HB) 1.3mm
Heavy weight valley troughs (DX,AX,HB) 2.10kg/m² Heavy weight throughs (DX,AX,BX) 1.6mm
Corodrain Diamond 60 
January Sale - 5% Off Orders Placed Online Over £150.00. - Ends On 8th Jan 2009
Heavy weight type B or D valleys with the addition of floride based patented surface protection. Provides complete protection against UV light, resistant to virtually all chemicals,solvents and pollutants,temperature range -40º to +100º. The durability of Diamond 60 has been recognised as matching code 7 lead by Housing Association Property Mutual (HAPM). Designed for very harsh environments or prestige building.

Sold in packs of 10